| How do I use the SomaticVision.bxd design for neurofeedback? |
|
The SomaticVision.bxd allows you to reward any one frequency
band and inhibit any one or two frequency bands. To begin open the SomaticVision.bxd design (in BioExplorer) and set your reward and inhibit bands. You can go to ‘Tools->Filters’ to adjust the frequency bands (12-15 Hz, etc.) then double click on the band you want to change (and enter your values) or click once and use the arrow keys (left-lower, right-higher, up-wider, down-narrower). Set both the Low and High inhibits to the same range if you wish to only use a single inhibit. The inhibits and the reward thresholds are set to auto-threshold
(percent success). You can adjust the percent success of the thresholds by double-clicking a threshold object in the Signal Diagram and changing the ‘Auto Target (Percent Success)’ value. The default low and high inhibits are broad, covering 0.5Hz – 38.0Hz. The default reward is 12.0Hz – 15.0Hz.
|
|
|
|